Security-Observation Technology
SPECTRA Control Panels
-
SPECTRA Control Panel
1727
- 6 zone inputs
- 8 user codes (no partitioning)
- 2 PGM outputs and 1 alarm relay
- 1 bell output and 1 auxiliary output
- 1.5A switching power supply
- No support for Spectra modules except keypads
-
SPECTRA Control Panel
1728 1686V/H Контролен панел 12 зони ( 5 дублирани+2 клавиатурни), с възможност за делене на две независими системи, разширение с до 8 зони, 2 PGM, BUS технология, комуникатор, клавиатура 1686 V/ H, Кутия 11х11"
-
SPECTRA Control Panel
1738 1686V/H Контролен панел 16 зони (7 дублирани + 2 клавиатурни), с възможност за делене на две независими системи, разширение с до 8 зони, 2 PGM, BUS технология, комуникатор, клавиатура 1686 V/ H, Кутия 11х11"
SPECTRA Control Panels SP Series
-
SPECTRA Control Panel SP
SP5500
- StayD mode
- 4-wire expansion bus
- 5 zone inputs or 10 with zone doubling, expandable to 32 zones
- 2 on-board PGMs
- Supports up to 16 PGMs
- 2 Partitions
- 32 User Codes
- 1.1A switching power supply
- In-field firmware upgradeable via a 307USB and WinLoad
- Menu-driven programming for the Installer, Master and Maintenance codes
- Multiple phone numbers: 3 for monitoring station, 5 for personal dialing and 1 for pager reporting
- Automatic Daylight Savings Time feature
- Push button software reset (reset to default values and restart)
- Direct connect at 9.6k baud with WinLoad
- 256 events buffered
- Fits in 20cm x 25.5cm x 7.6cm (8in x 10in x 3in) and 28cm x 28cm x 7.6cm (11in x11in x 3in) metal boxes
-
SPECTRA Control Panel SP
SP6000
- StayD mode
- 4-wire expansion bus
- 8 zone inputs or 16 with zone doubling, expandable to 32 zones
- 2 (+2 optional) on-board PGM outputs, positive or negative triggering
- Supports up to 16 PGMs
- 2 Partitions
- 32 User Codes
- 1.5A switching power supply
- 1 alarm relay (optional)
- In-field firmware upgradeable via a 307USB and WinLoad
- Menu-driven programming for the Installer, Master and Maintenance codes
- Multiple phone numbers: 3 for monitoring station, 5 for personal dialing and 1 for pager reporting
- Automatic Daylight Savings Time feature
- Push button software reset (reset to default values and restart)
- Direct connect at 9.6k baud with WinLoad
- 256 events buffered
- Fits in 20cm x 25.5cm x 7.6cm (8in x 10in x 3in) and 28cm x 28cm x 7.6cm (11in x11in x 3in) metal boxes
-
SPECTRA Control Panel SP
SP7000
- StayD mode
- 4-wire expansion bus
- 16 zone inputs or 32 with zone doubling, expandable to 32 zones
- 4 on-board PGM outputs, positive or negative triggering
- Supports up to 16 PGMs
- 2 Partitions
- 32 User Codes
- 1.5A switching power supply
- 1 alarm relay
- In-field firmware upgradeable via a 307USB and WinLoad
- Menu-driven programming for the Installer, Master and Maintenance codes
- Multiple phone numbers: 3 for monitoring station, 5 for personal dialing and 1 for pager reporting
- Automatic Daylight Savings Time feature
- Push button software reset (reset to default values and restart)
- Direct connect at 9.6k baud with WinLoad
- 256 events buffered
- Fits in 20cm x 25.5cm x 7.6cm (8in x 10in x 3in) and 28cm x 28cm x 7.6cm (11in x11in x 3in) metal boxes